Dissolved Oxygen Probe Accessories
- (4)
- (1)
- (3)
- (3)
- (1)
- (1)
- (1)
- (2)
- (2)
- (2)
- (5)
- (1)
- (2)
- (2)
- (1)
- (3)
- (1)
- (2)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
Filtered Search Results
MILWAUKEE INSTRUMENTS OXYGEN ELECTROLYTE SOLUTION
NC1977884 OXYGEN ELECTROLYTE SOLUTION
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Enterprise Technology Solutions 113R00674 TRANSFER UNIT, 400000 PAGE-YIELD
Extends the life of your printer. Delivers reliable print quality. Enables efficient device operation.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sigma Aldrich Fine Chemicals Biosciences DuolinkR In Situ PLAR Prob
Duolink(R) In Situ PLA(R) Probe Anti-Mouse MINUS contains affinity purified donkey anti-mouse IgG (HL) which reacts with whole molecule mouse IgG and also reacts with the light chains of other mouse immunoglobulins.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bioanalytical Systems Inc EC C2 CELL TOP
Cell Top; PTFE; For C-3 or CGME voltammetry cell *Does not ship to Puerto Rico
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
YSI 3P LifeScience MEM CAPS FOR CELLOX 325 3/PK
3 exchange membrane heads for all sensors, except StirrOx G and DurOx 325.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
HANNA INSTRUMENTS INC Zero Oxygen Solution Set (500 mL)
HI7040L is a high quality, bicomponent zero oxygen solution made from reagent grade chemicals. Hanna dissolved oxygen solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.Prepared with reagent grade chemicalsHassle-free, easy to mix chemical component bottlesAir-tight seal to ensure the quality of the solution
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Probe PTFE,12x320mm Mettler
Cathode platinumAnode silverPolarization 675mvOutput 40 to 70na in air at 25cTemperature 0 to 60c sterilization to 130cStability 2 or readout per week at constant pressure temp 30cLinearity better than 03 of readoutPressure 60psi maximumConnector 4 pin Bendix--Material welded parts 316L stainless steel
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company Replacement Membranes for Dissolved Oxygen Probe
Replacement membranes (package of two) for sensION+ 5130 (article number LZW5130.97.0002) and sensION (article number 5197000) DO Probes.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cole-Parmer Oakton DO Probe Replacement Electrolyte Solution
Oakton DO Probe Replacement Electrolyte Solution
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
METTLER TOLEDO Transmitter M800 Process 4-CH
The four-channel M800 Process is a multi-parameter transmitter that provides high-performance, reliable measurement with a convenient full-color touch screen and the ability to integrate with a wide range of ISM and analog sensors
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
METTLER TOLEDO InPro 5000 Co2 Sensor Membrane Kit
InPro 5000 Co2 Sensor Membrane Kit.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
YSI 3P LifeScience STANDARD MEMBRANE KIT 150/PKS
5793 Membranes, 150-Pack, Standard
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bioanalytical Systems Inc EC RDE-2-CELL TOP
Cell Top; PTFE; For RDE-2 voltammetry cell *Does not ship to Puerto Rico
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Hach Company SELF-ZEROING AUTO BURET 25 ML
5000207609 SELF-ZEROING AUTO BURET 25 ML
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Probe W/VP,12x225mm With VP Connection - Ingold
Measurement principle: amperometric / polarographicPressure resistance measurement: 0.2 – 6 bar absoluteMechanical pressure resistance: max. 12 bar (174.0 psi) absoluteMeasuring temperature range: 0 – 80°c (32 – 176°f)--Temperature range: -5 – 140°C (23 – 284°F)-- Temperature compensation: automatic with builtin RTD--Cable connection: vario pin (ip68)-- O-Ring material: Viton, silicone (FDA approved)-- Membrane material: Teflon / silicone / Teflon (reinforced with steel mesh)--Quick disconnect interior body: standard--Cathode: pt--Anode: ag--Guard ring: no--Detection limit: 6ppb--Accuracy: 1% or 4ppb--Response time @25°C (air to n2): 98% of--final value <90s-- Sensor signal in ambient air (25°C): 40 – 110na-- Residual signal in oxygen-free medium: <0.1% of the signal in ambient air.--Max. Flow error: less than or equal to: 5%-- Certification: EHEDG, 3a, 3.1b (en 10204.3.1b)
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More